Customization: | Available |
---|---|
Certification: | ISO9001, CE |
Salt Rejection Rate: | 98.0% |
Still deciding? Get samples of US$ 7998/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
What is Reversed Osmosis?
Reverse osmosis (RO) technology is a high-tech water treatment technology, it relies on the reverse osmosis membrane under pressure to make the solvent and solute in the solution of the characteristics of the work. "Penetration" is a physical phenomenon, reverse osmosis is the containing salt, and various small impurities in water (raw water) greater than natural osmotic pressure, the water from the high concentration of reverse osmosis from one side to the low concentration, and the vast majority of minor impurities in raw water, organic matter, heavy metals, bacteria, viruses and other harmful substances, such as the sewage outlet discharge.
At present, RO process has occupied markets rapidly by the advantages of easy operation, easy maintenance and equipment modular, and begin to be the most widespread ways of instead of distillation step by step.
XST reverse osmosis water treatment system uses pre-treatment device, including quartz sand filter, activated carbon filter, water softener(anti-scale doing system), security filter and RO reverse osmosis system, with the multiple filtration and separation of water ion technology, the salt and bacteria removal rate can reach 97%-99%, thus providing safe and pure water
Name
|
Capacity
(Tons/Hr)
|
Operation (Mpa)
|
Feed Inlet (MM)
|
Membrane Size ( Inch)
|
Recovery
|
Power
(KW)
|
XSTRO-250L
|
0.25
|
1.0-1.4
|
DN20
|
40*40
|
50%
|
1.1
|
XSTRO-500L
|
0.5
|
1.0-1.4
|
DN20
|
40*40
|
50%
|
1.5
|
XSTRO-750L
|
0.75
|
1.0-1.4
|
DN25
|
40*40
|
60%
|
2.2
|
XSTRO-1000L
|
1.0
|
1.0-1.4
|
DN25
|
40*40
|
60%
|
2.2
|
XSTRO-1500L
|
1.5
|
1.0-1.4
|
DN25
|
40*40
|
60%
|
3.0
|
XSTRO-2000L
|
2.0
|
1.0-1.4
|
DN25
|
40*40
|
60%
|
3.0
|
XSTRO-250LDP
|
0.25
|
1.0-1.4
|
DN20
|
40*40
|
50%
|
2.6
|
XSTRO-500LDP
|
0.5
|
1.0-1.4
|
DN25
|
40*40
|
50%
|
3.7
|
XSTRO-1000LDP
|
1.0
|
1.0-1.4
|
DN25
|
40*40
|
60%
|
5.2
|
XSTRO-2000LDP
|
2.0
|
1.0-1.4
|
DN25
|
40*40
|
60%
|
7.0
|
XSTRO-3
|
3.0
|
1.0-1.4
|
DN32
|
40*40
|
70%
|
4.0
|
XSTRO-6
|
6.0
|
1.0-1.4
|
DN40
|
80*40
|
70%
|
5.5
|
XSTRO-10
|
10.0
|
1.0-1.4
|
DN50
|
80*40
|
75%
|
11
|
XSTRO-15
|
15.0
|
1.0-1.4
|
DN50
|
80*40
|
75%
|
15
|
XSTRO-20
|
20.0
|
1.0-1.4
|
DN65
|
80*40
|
75%
|
18.5
|
Reverse osmosis(RO) system
Reverse Osmosis (RO) Membrane
Reverse osmosis process is the world's advanced, energy-saving and effective separation technology now, with a filtration accuracy of 0.001 μm, to completely separate and remove all particles of soluble salts, colloids, organics, microorganisms, viruses,bacteria, rust, and heavy metals in water. It requires pressure to force pure water across a membrane, leaving the impurities behind.
However, note that reverse osmosis systems are not ideal for treating water that is very hard and/or with significant quantities of contaminants. In this case, to extend the operating life of the membrane, the water should be pre-treated before entering reverse osmosis membranes (filtering, deferrization, etc.).
S/N. | Process | Application |
1 | Raw water tank | Store water, buffering pressure, overcome instability of supplying water by pipe, ensure to supply water stably and continuously for whole system. |
2 | Raw water pump / booster pump | Provide rated pressure for the pre-treatment filters, and we use one pump for use and the other one for standby, which can ensure the stable operation of the equipment. If one pump is faulty, the other pump will work to ensure that the water into the RO equipment will not be affected |
3 | Flocculant dosing system | The role of flocculant is to make the tiny colloids, suspended solids, and even organic matter in water forming large particles suspension (granules) by electro-neutralization, coagulation, bridging, and net trapping, so that these granules can be removed in the multi-media filter. |
4 | Multimedia Filter | FRP material as the filter housing, fill with quartz sand and anthracite inside, and mainly filter the particles, suspended matter, colloids and microorganisms of raw water. Usually the effluent quality of quartz sand filter can reach SDI<1 and turbidity<5; |
5 | Anti-scale dosing system | Scale inhibitor dosing can prevent the scaling of sulfate and prevent the damage of membranes such as calcium sulfate, especially the damage of crystalline crystals of BaSO4 and SrSO4. It also acts as a dispersing agent for iron colloids and fine particles, protect the membrane. |
6 | Security filter/PP filter | Prevent large particles, bacteria, viruses into RO membrane, accuracy is 5μm |
7 | High pressure Pump | Provide needed working pressure for RO system, ensure production capacity of pure water. (CNP pump or customer-specified) |
8 | Reverse osmosis(RO) system | Can remove particles, colloids, organic impurities, heavy metal ions, bacteria, virus, heat source etc. harmful substances and 99% dissolved salts. |
9 | Chemical Cleaning system (Optional device) | It refers to the use of acid, alkali, organic chelating agents, dispersants and other chemical agents, to dissolve and remove dirt and scale attached to the metal surface. There are pickling, alkali washing, ammonia washing, sludge stripping, solvent cleaning and so on. |
10 | Electrical Control Cabinet | Automatic control, Relay /PLC/HIM as optional |