ISO/CE Approved 50t/H Well Underground Water Purification System

Product Details
Customization: Available
Certification: ISO9001, CE
Salt Rejection Rate: 99.0%
Still deciding? Get samples of US$ 80000/set
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
52
Year of Establishment
2010-08-17
  • ISO/CE Approved 50t/H Well Underground Water Purification System
  • ISO/CE Approved 50t/H Well Underground Water Purification System
  • ISO/CE Approved 50t/H Well Underground Water Purification System
  • ISO/CE Approved 50t/H Well Underground Water Purification System
  • ISO/CE Approved 50t/H Well Underground Water Purification System
  • ISO/CE Approved 50t/H Well Underground Water Purification System
Find Similar Products

Basic Info.

Model NO.
XSTRO-50T
Application
Industry
Capacity
50t/H
Product Name
50t/H Underground Water Purification System
Applications
Drinking,Agriculture, Bottling,Industrial,etc
Raw Water TDS
<1500ppm
Raw Water Chloride
<1000ppm
Pure Water TDS
<100ppm
Voltage
380V/220V/240V;50Hz
Recovery Rate
60%-75%
Material
Carbon Steel, Stainless Steel 304/316,FRP
Key Words
Water Filtration System Reverse Osmosis System Wa
Processing
Pre-Filters+RO Water Purification Plant
Frame Material
Stainless Steel 304/ Carbon Steel Paint
Core Components
Pressure Vessel, Pump, RO Membranes, Control...
Weight
8000kgs
Precision Filter
PP/ABS Filter Element
Brand Name
Xst
Transport Package
Container
Specification
8.0m*1.7m*2.0m
Trademark
XST
Origin
China
HS Code
8421219990
Production Capacity
100sets/Month

Product Description

ISO/CE Approved 50T/H Well Underground Water Purification System
ISO/CE Approved 50t/H Well Underground Water Purification System
Reverse osmosis (R.O.) water treatment plant is one of the most advanced technologies to purifier water by using the pressure difference of semi permeable/reverse osmosis membranes to purify. RO system is the core components of pure water filtration plant. It is effective to remove asbestos, many taste, color, odor producing chemicals, particulates, calcium,magnesium, bacterials, turbidity and radium etc.Thus, it can purify underground water, tap water, lake, river, seawater, blackish water etc, and widely be used in food&beverage,pharmaceutical,chemical industry, electronic industry etc.

XST reverse osmosis water treatment system uses pre-treatment device, including quartz sand filter, activated carbon filter, anti-scale dosing system, security filter and RO reverse osmosis system, with the multiple filtration and separation of water ion technology, the salt and bacteria removal rate can reach 97%-99%, thus providing safe and pure water.
ISO/CE Approved 50t/H Well Underground Water Purification System
 
Model Capacity Operation Feed inlet Membrane Membrane Desalination Recovery Power
(T/H) (MPa) (MM) Size(Inch) (Qty) (KW)
XSTRO-0.25T 0.25 1.0-1.4 DN20 40×40 1 ≥97% 60-80% 2
XSTRO-0.5T 0.5 1.0-1.4 DN20 40×40 2 ≥97% 60-80% 2.5
XSTRO-0.75T 0.75 1.0-1.4 DN25 40×40 3 ≥97% 60-80% 3
XSTRO-1 1 1.0-1.4 DN25 40×40 4 ≥97% 60-80% 3.3
XSTRO-2 2 1.0-1.4 DN25 40×40 8 ≥97% 60-80% 4.5
XSTRO-3 3 1.0-1.4 DN32 40×40 12 ≥97% 60-80% 8
XSTRO-5 5 1.0-1.4 DN40 80×40 5 ≥97% 60-80% 16
XSTRO-10 10 1.0-1.4 DN50 80×40 10 ≥97% 60-80% 22
XSTRO-15 15 1.0-1.4 DN50 80×40 15 ≥97% 60-80% 32
XSTRO-20 20 1.0-1.4 DN65 80×40 20 ≥97% 60-80% 42
XSTRO-30 30 1.0-1.4 DN80 80×40 30 ≥97% 60-80% 55
XSTRO-40 40 1.0-1.4 DN100 80×40 40 ≥97% 60-80% 65
XSTRO-50 50 1.0-1.4 DN125 80×40 50 ≥97% 60-80% 65
                                
Reverse Osmosis (RO) Membrane
Reverse osmosis process is the world's advanced, energy-saving and effective separation technology now, with a filtration accuracy of 0.001 μm, to completely separate and remove all particles of soluble salts, colloids, organics, microorganisms, viruses, bacteria, rust, and heavy metals in water. It requires pressure to force pure water across a membrane, leaving the impurities behind.
However, note that reverse osmosis systems are not ideal for treating water that is very hard and/or with significant quantities of contaminants. In this case, to extend the operating life of the membrane, the water should be pre-treated before entering reverse osmosis membranes (filtering, deferrization, etc.).
ISO/CE Approved 50t/H Well Underground Water Purification System


Reverse osmosis(RO) system
XST reverse osmosis water treatment system uses pre-treatment device, including quartz sand filter, activated carbon filter, water softener, security filter and RO reverse osmosis system, with the multiple filtration and separation of water ion technology, the salt and bacteria removal rate can reach 97%-99%, thus providing safe and pure water.
Working Process Chart:
Raw water tank→ Booster water pump→ Quartz sand filter→ Activated carbon filter→ Anti-scale dosing system→Security filter → High pressure pump→Reverse osmosis system→UV/Ozone generator → Pure water tank
ISO/CE Approved 50t/H Well Underground Water Purification System


Description of Main Parts
S/N. Process Application
1 Raw water tank Store water, buffering pressure, overcome instability of supplying water by pipe, ensure to supply water stably and continuously for whole system. (Customer provide, because big size will result in expensive freight.)
2 Raw water pump / booster pump Provide needed pressure for the pretreatment filters
3 Quartz sand filter/Mechanical filter FRP or stainless steel vessel as housing, fill quarts sand, it can filter big particles impurities, suspended substances, colloids etc.
4 Activated carbon filter FRP or stainless steel vessel as housing, fill activated carbon, remove color, odor, residual chlorine and organics substances.
5 Water softener/ demineralizer/ Na+ exchanger Adopt cation resin to Soften water, cation resin will absorb Ca2+, Mg2+(main elements for composing scale), reduce hardness of raw water, System can make resin intelligently regenerate, recycling
6 Security filter /PP filter Prevent large particles, bacteria, viruses into RO membrane, accuracy is 5μm,
7 High pressure Pump Provide needed working pressure for RO system, ensure production capacity of pure water. (CNP pump or customer-specified)
8 Reverse osmosis(RO) system Can remove particles, colloids, organic impurities, heavy metal ions, bacteria, virus, heat source etc. harmful substances and 99%
dissolved salts. (RO membranes USA Filmtec, Toray, LG,Vontron or customer-specified)
9 Electrical Control Cabinet Automatic control, Relay /PLC/HIM as optional
ISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification System
ISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification System

ISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification System
 

ISO/CE Approved 50t/H Well Underground Water Purification System
What types of water sources does it treat?

Reverse Osmosis is an ideal water treatment solution in most types of water.tap water, also known as municipal sources, undergroundwater, which includes brackish water, and saltwater. The biggest distinction between these three types is the Total Dissolved Solids (TDS) content of each type. As a rule of thumb, the American Health Association requires that drinking water is under 2,000 PPM TDS.Reverse osmosis is often used in a tap water environment to reduce hardness, or the debris deposited in water from traveling in metal pipes. Total dissolved solids is often a target of water purification in tap water systems.Underground reservoirs of water are often brackish, meaning they contain large volumes of salt, but not enough to be considered salt water. Groundwater is most often purified for the agriculture industry, the mining industry. Groundwater is also a prized target of the bottling industry, because the unique mineral combinations often have an appealing taste.
Salt water reverse osmosis (sometimes referred to as desalination) is the turning of saltwater into drinking water. Ocean water has up to 45,000 PPM TDS. The biggest uses of desalination come in providing water in areas that lack a regular supply of fresh water. 

 

Is pretreatment necessary?

It is very important that feed water be preconditioned to protect the membranes from fouling causing premature failure.The membrane is constructed of a porous material that allows water to pass through, but rejects up to 99% of the dissolved solids at the surface. The dissolved salts are concentrated reject water (brine stream), where they are discharged to waste. Removing things prior is key to letting the RO system do what it was meant to do.As the RO System continues to operate, the dissolved and suspended solids in the feed water tend to accumulate along the membrane surface. If these solids are allowed to build up, they eventually restrict the passage of water through the membranes, resulting in a loss of throughput. (The throughput capacity of the membranes is commonly referred to as the flux rate, and is measured in gallons per square foot of membranes surface area per day.)

Is it necessary to get a water analysis?

A detailed chemical analysis (LSI, SDI, or CFI) of the RO feed water is an absolute necessity for identifying potential foulants. This should include a measurement of the hardness (calcium and magnesium), barium, strontium, alkalinity, pH, and chlorine. The data from the chemical analysis can be used by the engineers designing the system to determine the optimum 

membrane array that will both minimize the tendency of scale and deposit formation and maximize the recovery and flux rate.

What determines the precise pretreatments for a particular RO?

In one word: analysis. Every source of water is different, and you never know what's in your water until you have it analyzed. The water analysis, LSI, SDI, or CFI values are used to determine the precise pretreatment requirements for a particular RO System. Since water supplies vary considerably from one location to another, each pretreatment requirement will be different.

Does the feed water need to be softened by the RO?

Ion exchange is a popular method for softening and reducing the potential for mineral scale formation on the membrane surface. Ion exchange softening uses sodium to replace scaleforming ions such as calcium, magnesium, barium, strontium, iron, and aluminum to prevent damage to the membrane elements. The sodium forms very soluble salts, which are readily rejected by the Reverse Osmosis System and do not readily form mineral scales on the membrane surface. A sodiumcycle softener is regenerated with sodium chloride brine. The spent regenerant, along with the softener rinse water, must be discharged to waste. It is because of this that ion exchange is recommended for applications that have high metal contents in the treated water.
 

 Is acid injection necessary?

 Just as acidic solutions aren't good for membranes, caustic solutions are equally damaging to membrane elements. Acid injection may be incorporated into the RO pretreatment system to control pH and minimize the scale-forming tendency of the feed water. Acid injection is indicated if the scale forming tendency of the brine stream is above +0.3 as measured by the LSI. Either sulfuric or hydrochloric acid can be used for this purpose. 
 

 What does an antiscalant do?

Antiscalants have been shown to be effective in extending the intervals between chemical cleanings of the RO membranes. These products are generally formulated to include inorganic phosphates, organophosphates, and dispersants. Some Antiscalant contain negatively charged polymers and dispersants that can react with cationic polymers that might be dosed up stream prior to the media filters. The Antiscalant must be compatible with these polymers; otherwise, the reaction product 

will foul the membranes.
 

 Do all systems require chemical cleaning?

 Despite all efforts to protect the system from fouling and lose flux, eventually the membranes will require chemical cleaning. A welldesigned RO system will include provisions for a cleaning skid to facilitate the cleaning process. The skid should include a chemical tank, solution heater, recirculating pump, drains, hoses, and all other connection and fittings required for accomplishing a complete chemical cleaning of the RO modules.

ISO/CE Approved 50t/H Well Underground Water Purification System                                                                  
Q1. Why I choose your company?
A1: Our factory has professional technical team and advanced production line.
100% factory quality assurance, 12 months warranty and lifetime maintenance;
Q2. Which machine should I choose?
A2: It depends on your inlet water quality and output water requirements, we have professional sales team and engineers team, welcome to inquiry.
Q3.: The logo, language and color can be customized?
A3: Yes, welcome you to sample custom, and also can provide the pictures or requirements for design.
Q4: Could you provide the picture and video for our retail advertising?
A4: Yes, high-definition pictures will be provided which can be used for your clients, your online shop or official website;
Q5: Do you provide installation and training?
A5: Yes, synchronous drawings and operation manual will be provided, and also we can send our technician to your site for installation or training if necessary.
Q6: What's your machine size?
A6: It depends on the output flow requirement and we can make changes according to your space.

ISO/CE Approved 50t/H Well Underground Water Purification System
ISO/CE Approved 50t/H Well Underground Water Purification System
ISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification SystemISO/CE Approved 50t/H Well Underground Water Purification System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier